Model Number : TX2/TEX2 Series

Certification : UL,CSA

Place of Origin : China

MOQ : 1pc

Price : Negotiable

Payment Terms : T/T, L/C, Western Union, MoneyGram,Paypal

Supply Ability : 1000pcs per month

Delivery Time : 3-7 working days

Packaging Details : Carton box

Refrigerant : R22

Material : Brass

Valve type : Thermostatic Expansion Valves

maximum working pressure : 36bar

maximum test pressure : 28 bar

Application : Air Conditioning System/ Heat pump/Chillers/ Freezer (Cabinet) /Traditional refrigeration systems

Contact Now

HVAC Thermostatic Expansion Valves valve body TX2/TEX2 R22/-40℃/-60℃ Inner/Outer balance with/without MOP

The thermostatic expansion valve is used to adjust the supply amount of the liquid refrigerant in the evaporator
The supply amount is controlled by the degree of superheat of the refrigerant
This valve is therefore particularly suitable for the supply of refrigerant liquid in a dry evaporator since the degree of superheat of the refrigerant at the outlet of the dry evaporator is proportional to the load of the evaporator
T2 and TE2 are typically replaceable flow port assemblies
For the same valve type and refrigerant, the matching flow port assembly can be applied to all types of valve body and evaporation temperature. The filling of the temperature sensing element depends on the evaporation temperature range.
T2 (internal balanced expansion valve) and TE2 (external balanced expansion valve) are available. A system with a dispenser must be fitted with an external balanced expansion valve
Double contact temperature sensing package can quickly feel the temperature changes within the evaporator, and easy to install.
T2, TE2-type expansion valve can withstand the impact of hot air defrost
In order to extend the service life, all the spool and seat are made of a special anti-wear alloy


Product Features:
◆ evaporation temperature range
◆ interchangeable flow port assembly
- Easier inventory
- Facilitates capacity matching
- Easier to repair
◆ refrigerant for the nominal R22 when the refrigerant is 0.5 ~ 15.5kW
(0.15 to 4.5 TR)
◆ Valve with MOP function can be provided to prevent damage to the compressor motor due to high evaporation pressure.
◆ Patented double contact temperature sensing package
- Quick and easy installation
- Good heat transfer between piping and temperature sensing package
◆ valve can provide a special temperature range


Technical Parameters:
◆ Maximum temperature
- Temperature after installation of the valve: 100 ° C
- Temperature package is not installed, the temperature of the temperature package: 60O ℃
◆ The highest test pressure: 36bar
◆ Allowable working pressure: 28bar
Flow number and cold volume comparison table: the liquid temperature before the valve is 41 ℃

Refrigerant Model No. Size Code no.
(Inch) N Series NM Series NL Series B Series
  Without MOP With MOP With MOP With MOP Without MOP With MOP
R22 TX2 3×4 068Z3206 068Z3208 068Z3224 068Z3226 068Z3207 068Z3228
TEX2 3×4 068Z3209 068Z3211 068Z3225 068Z3227 068Z3210 068Z3229
R407C TZ2 3×4 068Z3496 068Z3516 --- --- --- ---
TEZ2 3×4 068Z3501 068Z3517 --- --- --- ---
R134a TN2 3×4 068Z3346 068Z3347 068Z3393 068Z3369 --- ---
TEN2 3×4 068Z3348 068Z3349 068Z3392 068Z3370 --- ---
R404A TS2 3×4 068Z3400 068Z3402 068Z3406 068Z3408 068Z3401 068Z3410
R507 TES2 3×4 068Z3403 068Z3405 068Z3407 068Z3409 068Z3404 068Z3411

Refrigerant Model no. Size Code no.
(Inch) N Series NL Series B Series
  Without MOP With MOP With MOP Without MOP with MOP
R22 TX2 3×4 068Z3281 068Z3287 068Z3366 068Z3357 068Z3319
TEX2 3×4 068Z3284 068Z3290 068Z3367 068Z3359 068Z3320
R407C TZ2 3×4 068Z3502 068Z3329 --- --- ---
TEZ2 3×4 068Z3446 068Z3447 --- --- ---
R134a TN2 3×4 068Z3383 068Z3387 --- --- ---
TEN2 3×4 068Z3385 068Z3389 --- --- ---
R404A TS2 3×4 068Z3414 068Z3416 068Z3429 068Z3418 068Z3420
R507 TES2 3×4 068Z3415 068Z3417 068Z3430 068Z3419 068Z3421

following table TGEX expansion valve can be replace some of the above table TX2 expansion valve (same conditions, similar cooling capacity)
Model No.
Cooling CAPACITY(R22)kW
-25℃/45℃ -10℃/45℃ 0℃/45℃
TGEX3 6.6 9 10.6
TGEX4 8.8 12.1 14.3
TGEX6 12.7 17.6 20.8


Cheap HVAC Thermostatic Expansion Valves valve body TX2/TEX2 R22/-40℃/-60℃ Inner/Outer balance with/without MOP for sale

HVAC Thermostatic Expansion Valves valve body TX2/TEX2 R22/-40℃/-60℃ Inner/Outer balance with/without MOP Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Star-Worths Refrigeration Co.,Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)